DESCALING YOUR BOILING CHAMBER Descale your water distiller every 2 to 3
months. 1)
Turn off the main power switch. 2)
Remove lid from boiling chamber. 3)
Add boiling hot water to the boiling chamber up to the scale line. 4)
Add 2 to 3 tablespoons of descaler to the boiling chamber and mix well. 5)
Let soak from 1/2 hour to overnight, depending on amount of scale
present. 6)
Drain the descaler solution from boiling chamber.
If build up is still present, try wiping the soft residue from the sides
with a cloth. If scale is still
present, repeat steps 3 and 4. 7)
After draining descaler solution, rinse boiling chamber by pouring 4
litres or more of water into
boiling chamber and drain once again, until all descaler residue has been
removed. 8)
Turn on main power, water, and fan switches and ensure water is coming
into boiling chamber. 9)
Replace lid on boiling chamber. 10) Your Water Distiller is now ready for operation. STERILIZATION OF THE COOLING COIL AND HOLDING TANKSterilize Your water distiller once or twice a
year. The following procedure uses steam to sterilize critical parts of your
distiller, therefore use caution when handling these pieces, as they become very
hot. 1)
Drain all water from bottom tank and unplug pump (if you have a pump.) 2)
Remove charcoal filter canister. 3)
Attach the sterilization drip tube on the end of the cooling coil and let
drip into bucket. 4)
Make sure the boiling chamber is full of water and turn the fan and water
switches to the off position. Leave
the main power switch on. 5)
Sterilize the cooling coil by letting the steam from the boiling chamber
run through it for approximately 20 minutes. 6)
Now place the sterilization drip tube into the holding tank for tank
sterilization. 7)
Open the distilled water spigot on the holding tank, place a pail
underneath. 8)
Let the water distiller sterilize for approximately 1 hour. 9)
Detach the sterilization drip tube and replace the charcoal filter
canister. 10)
Close the distilled water spigot and turn all switches on. CHANGING THE STAINLESS STEEL
CHARCOAL FILTER Change your charcoal filter every 3 months. 1)
Remove the stainless steel charcoal filter canister from the water distiller. 2)
Remove the top and screen and empty the old charcoal into the garbage. 3)
Rinse the canister thoroughly. 4)
Fill the canister 2/3 full of new activated coconut charcoal. 5)
Replace screen and lid. 6)
Rinse away any charcoal dust by running boiling hot distilled water through the
canister 2 to 3 times until the water runs clear. 7) Replace canister on the water distiller. Copyright © 1996 - 2003 Distiller Warehouse Ltd. #124, 9704 - 39 Avenue Edmonton, Alberta, Canada T6E 6M7 Phone:
(780) 437-0303, Fax: (780) 437-2995 Email: distiller@distillerwarehouse.com |